UK AAIB AAIB-2007-GDPJR · UK AAIB · Field investigation

Sikorsky S-76B Spirit

Approaching Coventry Airport · 2007-11-22·G-DPJR

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
No injury
highest injury
—
damage

What happened

AAIB synopsis, verbatim

Sikorsky S-76B Spirit, G-DPJR Summary: During cruise, whilst operating on a night positioning flight, the aircraft’s auxiliary heater system overheated, melting the surrounding ducting and progressively filling the cockpit with smoke. The crew declared an emergency and expedited their landing, the smoke and heat subsided once the aircraft had been shut down on the ground. The electronic control box for the heater was removed and subsequently confirmed to have failed, probably disabling the overheat protection and cockpit controls for the system. One Safety Recommendation is made.

Conclusion

the AAIB's conclusion, verbatim
Analysis Component failures within the control box for the cabin ECS resulted in the controller shutting down. This probably prevented operation of the left fan and the overheat protection system, but did not isolate power to the left heating element, which continued to operate. As a consequence of the lack of airflow over the heating element, the surrounding plastic ducting and trim overheated and generated smoke which slowly filled the cabin and cockpit of the aircraft. The crew were unable to isolate power to the heating element due to the loss of authority of the cockpit switches following the controller failure. As the aircraft slowed, the flow of ram air which had been flowing through the heating duct reduced and overheating of the ducting and surrounding trim became more severe. The resulting increase in smoke forced the crew to make an emergency landing. Tripping of the circuit breaker for the vent blower may have been unrelated to the cabin ECS control box failure. However, the loss of the auxiliary system fan, in addition to the vent blower, meant that the airflow through the duct was significantly reduced from normal operation, contributing to the severity of the overheat. As the existing design does not provide for either automatic or crew-selected isolation of this system, the aircraft manufacturer has considered a number of options to resolve the issue. There are a limited number of these systems still in service and one option would be to disable these, pending a design change. The following

Safety recommendations

1 issuedwhat changed because of this accident
  • AAIB 2009-033issued

    It is recommended that the Federal Aviation Administration require Sikorsky Aircraft to provide the flight crew with the means to isolate the 115 volt ac power supply to the auxiliary heater elements in the event of failure of the cabin Environmental Control System (ECS) controller fitted in S-76B helicopters, and that the power supply to the auxiliary heater is disabled until that means is provided.