UK AAIB AAIB-2007-GBYCP · UK AAIB · Field investigation

Beechcraft B200 Super King Air

Southend Airport, Essex · 2007-03-24·G-BYCP

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
No injury
highest injury
—
damage

What happened

AAIB synopsis, verbatim

Beech B200 Super King Air, G-BYCP Summary: After selecting the landing gear to UP after takeoff from Caen, the ‘gear unsafe’ light remained on. The flight crew established that the nose landing gear had neither retracted nor remained locked down and, despite recycling the gear and attempting to use of the emergency gear lowering system, the crew were unable to lock the leg down. On landing at Southend Airport, the nose leg collapsed, causing damage to the fuselage nose structure and the propeller blade tips. The investigation revealed that the nose gear actuator had been affected internally by corrosion, resulting from water ingress, which led to the failure of the threads within the actuation nut of the actuator. It had completed a total of 1,449 cycles of its 8,000 cycle life, but only 532 cycles since its last 1,000 cycle check.

Conclusion

the AAIB's conclusion, verbatim
Discussion Examination of the nose landing gear actuator revealed that a complete failure of the internal threads in the aluminium bronze nut had occurred. The threads had stripped and, hence, the input from the landing gear motor/gearbox could not cause the nut assembly to traverse the screw. A considerable amount of aluminium bronze wear debris was present in the grease on the screw thread, which suggested that the nut had been wearing over a period of time prior to failure. Examination of the grease showed that it was contaminated with water, which is likely to have reduced its lubrication properties, leading to increased wear and corrosion damage of the screw. Also, the corrosion pits formed were likely to have increased the roughness of the screw and accelerated wear of the nut. This wear would have progressively reduced the load bearing capacity of the thread to a point when it could no longer support normal operating loads, leading to a failure of the remaining thread profiles. As the problem with the nose landing gear actuator was downstream of the emergency system input, it was not possible to lock the nose landing gear down. Other incidents on B200 aircraft also showed corrosion and increased wear, due to lack of lubrication. Although the nose landing gear actuator in G-BYCP was a PMA part, the corrosion and lack of lubrication could equally have occurred to an OEM part since the only difference in design is the method of attaching the plug (nut) insert. The presence of excessive play at the 1,000 cycle end play check would indicate increased wear and, as such, an actuator would normally be returned for overhaul. However, the actuator from C‑GISH ‘failed’ only 89 

Safety recommendations

1 issuedwhat changed because of this accident
  • AAIB 2007-126issued

    It is recommended that the Federal Aviation Administration require Raytheon (Beechcraft) to review the maintenance requirements of the nose landing gear actuator fitted to the Beech B200 King Air series of aircraft, and any other model using a similar design of actuator, with regard to the requirement of periodic lubrication and the periodicity of inspections.