What happened

AAIB synopsis, verbatim

Cameron Z-350 Balloon, G-CCSA Summary: Although the forecast included a 30% probability of thunderstorms, the local weather conditions were fine when the balloon launched from a field outside the town of Monmouth. About 40 minutes into the flight, some of the occupants of the balloon basket observed lightning to the south and east. Approximately 15 minutes later, prompted by the sound of thunder, the pilot made an approach to land in the area that he had previously selected for the end of the flight. This approach was abandoned because of fluctuating winds and the presence of wires across the landing path. Another attempt to land was aborted before the pilot made an emergency landing in gusty wind conditions onto uneven ground. During the hard landing the pilot and one passenger received serious injuries and the other 13 passengers sustained minor injuries. Following the accident the operator reviewed their decision-making procedures prior to take off. Two recommendations regarding the operator’s procedures and safety equipment have been made.

Conclusion

the AAIB's conclusion, verbatim
Discussion The balloon was beneath the western edge of a cumulonimbus cloud when it made an emergency landing. It was not possible to establish the balloon’s ground speed or the surface wind velocity during the landing, but the weather forecast for the period indicated that the wind speed could gust to 30 kt in, and near to, thunderstorms. The pilot had earlier made two attempts to land but was unable to do so due to obstacles and insufficient control of the balloon. The weather then deteriorated rapidly. The initial attempt was made in the vicinity of Betts Newydd, the planned landing area. As the balloon flew further west, the weather worsened and suitable landing sites did not present themselves as the balloon travelled over difficult landing terrain. When the pilot decided to make an emergency landing he was faced with a combination of a strong surface wind, which was probably in excess of the manufacturer’s limiting surface wind for a landing, and an uneven landing surface. These conditions, which were not foreseen and fell outside the operator’s operating limitations, fell within the criteria for passengers to wear protective helmets. The meteorological aftercast reflected the conditions that the pilot observed before the balloon took off and during the first half of its flight. The aftercast also indicated that any cumulonimbus cloud would not have been visible until it was quite close to the observer.

Safety recommendations

2 issuedwhat changed because of this accident
  • AAIB 2006-132issued

    It is recommended that Ballooning Network Ltd review their procedures to ensure that suitable alternative landing areas are identified in their spheres of operation in the event that a planned landing area cannot be used.

  • AAIB 2006-133issued

    It is recommended that Ballooning Network Ltd review their safety equipment, particularly with regards to the provision of protective helmets, to cater for possible emergencies