Reims Cessna F172N
900 ft above Snetterton, Norfolk · 2006-10-28·G-BHDZ
What happened
AAIB synopsis, verbatimReims Cessna F172N, G-BHDZ Summary: An electrical system failure which occurred in-flight, but close to an airfield, resulted in flames and smoke emanating from behind the left instrument panel, after the pilot attempted to re-set the alternator circuit breaker. During short final approach to the airfield for a precautionary landing, the engine stopped and the aircraft landed in a field close to the runway. A combination of a defective battery and a failure of the voltage regulator was identified as the main causal factor of this event. Two safety recommendations are made.
Conclusion
the AAIB's conclusion, verbatimDiscussion The evidence suggests that the alternator circuit breaker probably tripped shortly after the engine was started, with this not being noticed by the pilot at the time. It is also likely that the poor condition of the temporary replacement battery accounted for the relatively short time period before the voltage deteriorated to the point where the fuel gauges and radio did not operate correctly. The probable failure mode of the regulator resulted in a high current being applied to the alternator field coil, and in consequence, a high alternator power output. Resetting the circuit breaker thus caused this output to be applied through the circuit breaker to the aircraft wiring, which melted the insulation and led directly to the smoke and flames. It is likely that a cascade of short-circuit conditions ensued within the wiring loom, to the extent that the pilot’s action of switching off the battery master was likely to have been ineffective. Almost certainly, the cause of the engine failure was due to the grounding of the magnetos as a result of wiring damage around the magneto switch. If the alternator circuit breaker indeed tripped at around the time the engine was started, it is perhaps not surprising that the pilot failed to notice it as the aircraft checklist, in common with those of most other light aircraft, only called for a check of the circuit breakers before engine start. It is generally understood, following incidents concerning wiring failures in Commercial Air Transport aircraft, that circuit breakers found to have tripped in flight should
Safety recommendations
2 issuedwhat changed because of this accident- AAIB 2007-048issued
It is recommended that the European Aviation Safety Agency, in conjunction with the Civil Aviation Authority, publish specific information aimed at discouraging the resetting of high power circuit breakers on light aircraft, such as those that control alternators, whilst in flight unless considered essential for the safe continuation of the flight. Although the potential problems identified by the FAA, affecting those Cessna single-engine aircraft equipped with 14v electrical systems, were unrelated to the G‑BHDZ incident, the information contained in SAIB CE-04-72 may be relevant to European registered aircraft. However, the SAIB issued by the FAA is considered a relatively obscure method of transmitting airworthiness information, and it is possible that many owners and operators are unaware of the potential vulnerability of their aircraft. The following Safety Recommendation is therefore made:
- AAIB 2007-049issued
It is recommended that the European Aviation Safety Agency, in conjunction with Civil Aviation Authority, promulgate the information contained in FAA Special Airworthiness Information Bulletin CE-04-72, so that European operators of single-engine Cessna aircraft, together with their maintenance organisations, can ensure that the aircraft electrical systems have the required level of over-voltage protection.