UK AAIB AAIB-2003-N125XX · UK AAIB · Field investigation

HS125-700A

Runway 26, London (Luton) Airport, Bedfordshire · 2003-06-13·N125XX

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
No injury
highest injury
—
damage

What happened

AAIB synopsis, verbatim

HS125-700A, N125XX

Conclusion

the AAIB's conclusion, verbatim
Discussion In the absence of any other possible causal factors, it has to be assumed that the LPT 1 disc failed due to disadvantageous adjustment of the throat areas of individual nozzles of the A-5 assembly. This resulted in a resonant excitation of the disc that applied stresses, beyond the design requirement, initiating and propagating high-cycle fatigue cracks that failed the disc at little more than 100 hrs running time from new. The repair station that performed the last overhaul had been supplied with the A-5 nozzle assembly by the spares dealer. The dealer required that it be overhauled, repaired as necessary and then adjusted to a particular total area before its return. The repair station was not aware of the contents of either SB TFE731-72-3367 or SB TFE731-72-3369RWK. Indeed, not being a Honeywell authorised repair station, they would not have been informed of the latter and not only remained ignorant of the manufacturer's required method of adjusting the vanes but also the correct tooling for the process and the 'NAPOLI' programme. When asked about the method they employed, the repair station replied that they had adjusted the nozzle area by "tweaking all the vanes an equal amount." They also admitted that they were ignorant of a Honeywell applied limit of 0.010 inches maximum differential between the largest and the smallest throat opening. It is deemed acceptable for some repair stations in the USA to operate without the benefit of all, or even any, Original Equipment Manufacturer (OEM) data; Airworthiness responsibility falling to the DER. This investigation demonstrates that important procedures, known only to the manufacturer and its approved agencies, were not performed by the repair station. This is considered potentially hazardous, particularly in the case of turbine engine parts that can be apparently very sensitive to minor variations in material or dimensions. The discrepancy between Honeywell's records for the A-5 nozzle and those supplied with the part remains a concern. The part may well have been the one to which the serial number referred, but its history clearly was not related. Post-incident remedial actions. The manufacturer intend to revise the LMM/IRM manuals adding a caution concerning the adjustment of nozzle vanes. They will also require inspection of all TFE731-2A/3 engine A-5 nozzles at the next MPI (or next access) to measure throat openings and evaluate using 'NAPOLI'. They are HS125-700A, N125XX also considering a requirement to scrap the LPT 1 disc if an unacceptable 'NAPOLI' solution is recorded. Additionally, the repair station involved is negotiating with Honeywell the purchase of a copy of the 'NAPOLI' programme and the associated tooling. Honeywell are also attempting to locate other agencies that may be performing work on the A-5 nozzle to ensure that they too are aware of the potential problems following vane adjustment. In the longer term, a new LPT 1 disc is being developed that will seek to avoid the resonance problems even with a disadvantageous arrangement of differential throat openings. It is understood however, that the requirement to work in accordance with the 'NAPOLI' criteria will remain.
In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.