UK AAIB AAIB-2003-GODNH · UK AAIB · Field investigation
Schweizer 269C-1
Pateley Bridge, Yorkshire · 2003-05-07·G-ODNH
Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
No injury
highest injury
—
damage
What happened
AAIB synopsis, verbatimSchweizer 269C-1, G-ODNH
Conclusion
the AAIB's conclusion, verbatimThe tail rotor fork bolt failed in fatigue after a period of operation with no pre-load present in the bolt/nut assembly. The lack of pre-load was probably a consequence of failure to establish the correct tension in the bolt at the time of last assembly. Failure to establish the correct tension may have resulted from a tight fit of the bolt within the threaded insert, disguising the fact that the bolt head was not correctly seated as torque was applied. Contamination of the bore of the threaded insert with teflon dust may have caused the tight fit of the bolt within the threaded insert. Torque tightening was an installation procedure detailed in the manufacturer's maintenance manual at the time the hub was refitted. Establishment of a measured bolt-stretch dimension was also a procedure detailed in the manual. The torque tightening procedure was used for the last installation but is no longer an installation method detailed in the manual. Implementation of a torque check of the tail rotor retaining nut is required 25 hours after installation of the fork bolt on all versions of the Schweizer 269 helicopter. This requirement applied to the C-1 version, the type of aircraft in question, at the relevant time but was not highlighted amongst the re- assembly instructions. Use of the bolt-stretch method of fitting (the only method now detailed) may have resulted in any incorrect seating of the bolt being identified at installation. Finally, implementation of the 25-hour torque check, if carried out, might have alerted maintenance staff to any incorrect tightening of the bolt. Given the atypical layout of the information within the HMI when the work was done, the oversight was, to some extent, understandable. The HMI has since been changed.
In FlarePath for this case
What an account opens
AnalyseThe Analyst and the S.I. Assistantone timeline across the recorders, precedent accidents, answers from the 1 documents with the page they came fromKeepCasebook and briefsnotes pinned to the evidence, an investigation brief, a read-only link for your team
The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.