SA332 SUPER PUMA

1 nm north of Miller Platform, North Sea · 2003-02-22·G-JSAR

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
No injury
highest injury
—
damage

What happened

AAIB synopsis, verbatim

Eurocopter AS332-L2 Super Puma, G-JSAR

Conclusion

the AAIB's conclusion, verbatim
Discussion Although neither of the two incidents described here occurred in the cruise, had they done so, the ability for continued safe flight was considered not to be compromised. Nevertheless, the fact that the MGB and the accessory modules share the same oil system could result in potentially serious contamination problems, thereby constituting a flight safety hazard. The concurrent loss of an AC generator and a hydraulic system represent an additional erosion of safety margins, and this is acknowledged by the Flight Manual requirement that the aircraft land as soon as possible. The two failure cases together with the large number of premature left hand module removals indicate that the component was introduced into service at an immature stage of development, with problems arising from the increased power requirement for the oil cooler of the L2 variant. The good service record of the module in earlier variants probably contributed to a lack of recognition that significant changes were required. The operators are understandably keen for a resolution to the problems with the module and have been working closely with the manufacturer, who has clearly dedicated considerable resources in attempting to find a remedy. In any case the close liaison between manufacturer and operator was already a necessary consequence of the HUMS systems, and this represents a change from historical relationships in that the manufacturer now plays an increasing part in the day-to-day serviceability and, by extension, the airworthiness of the aircraft. The degree of the manufacturer's involvement will vary from one operator to another. The UK operators have dedicated and experienced HUMS teams, whose experience allow rather more autonomy than the operator of, say, a single aircraft, who may be almost entirely dependant on the manufacturer's specialists for guidance. The complex nature of HUMS underscores the necessity for effective communications between the operator and manufacturer, as well as the ability to interpret the data. With regard to the latter, the two incidents are illustrative of the learning process. Certainly, in the case of G-JSAR, the advice to continue to 'close monitor' for 50 flight hours following the alert on 12 February 2003 is unlikely to be repeated in the future, given a similar set of data. Similarly, trends and threshold breaches in the G- PUMS data were found to have provided indications that all was not well. Thus the experience gained in these incidents should in future result in earlier decisions to remove a gearbox module before a damage condition progresses to failure, thereby preventing a component reliability issue from escalating to one of flight safety. HUMS has its origins in a recommendation of the HARP (Helicopter Advisory and Review Panel) report of 1984, which led to the United Kingdom Civil Aviation Authority (CAA) funding trials between 1987 and 1991, culminating in two production standard systems entering service in 1991. The major challenge was to develop systems capable of providing warnings of impending failure of the many critical components in the drivetrain, and the UK AAIB was able to identify six UK accidents in the 1980's that HUMS could have prevented. During the 1990's HUMS systems routinely identified in-service problems and were instrumental in achieving a significant reduction in the number of incidents of serious in-flight vibration. By 1997 the CAA concluded that HUMS were able to provide valid warnings in 60% of all potentially catastrophic failure cases. It is therefore clear that the introduction of HUMS has improved the safety of flight in helicopters. In the UK, vibration health monitoring systems have been made mandatory on large helicopters certified or validated since certification requirements were tightened by the CAA after the HARP report, by the introduction of the so called 'design assessment requirements' (subsequently incorporated into the JAA and FAA certification requirements). In 1999 an Additional Airworthiness Directive (AAD) was introduced which made vibration health monitoring systems mandatory in the UK on older types carrying more than nine passengers. Finally, although HUMS is offered as an option by Eurocopter, the United Kingdom remains the only country in the European Union (EU) where such systems are mandatory, although all helicopters operating in the North Sea, regardless of state of registration, currently have them. (The AS332-L2 is slightly different in that HUMS is treated as a condition of Type Certificate validation in the UK). It should be noted that on 28 September 2003, responsibility for the airworthiness standards for most of Eurocopter AS332-L2, Super Puma, G-JSAR the civil aircraft registered in the member states of the EU passed to the European Aviation Safety Agency (EASA). This change has resulted in approximately 95% of UK CAA AAD's being
In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.