UK AAIB AAIB-2003-GDOCE · UK AAIB · Field investigation

Boeing 737-436

In flight near Lyon, France · 2003-05-30·G-DOCE

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
Minor injury
highest injury
—
damage

What happened

AAIB synopsis, verbatim

Boeing 737-436, G-DOCE

Conclusion

the AAIB's conclusion, verbatim
Analysis From the evidence it is clear that the de pressurisation event on G-DOCE resulted directly from a wiring failure in a loom at the rear of the aft cargo hold. The initiation of the failure was probably due to fretting of the wiring insulation against a 'p-clip' or 'zip' strap, which allowed the conductors to become exposed and short to each other. It is likely that this allowed erroneous signals to be sent to the OFV, causing it to start to open, thus increasing the cabin altitude. The AUTO system then failed and passed control to the STBY system. However, as the cabin altitude continued to climb, the STBY light extinguished which indicated that this system had also failed. As the wires for the STBY system run through the same loom as those for the AUTO system, it was likely that an erroneous signal was picked up by the pressure controller, causing it to fail the back-up system. AC MAN was then selected but, as the OFV AC feedback wire was damaged, the indicator on the PCP appeared to show that the valve was closed and not responding to any switch inputs, whereas the valve was probably operating. The QAR data showed that the OFV must have been partially closed, as the cabin pressure remained in excess of ambient during the ensuing descent; if the valve had remained in the position associated with the de-pressurisation, the cabin altitude would eventually have matched the aircraft altitude. The quick actions of the crew to recognise the pressurisation failure and to initiate a descent prevented the cabin altitude climbing over 14,000 feet and thus prevented the automatic deployment of the cabin oxygen system masks. The injuries sustained by several passengers were relatively minor and would Boeing 737-436, G-DOCE have been related to the initial rapid decrease in cabin pressure when the OFV opened in response to a false signal. The results of the wiring loom examination revealed that its failure was most likely triggered by the abrasion of the insulation of two or more of the affected wires. This may have been caused by the 'p-clip' or the loom 'zip' straps in response to normal vibration and associated movement of the loom, especially if they had not been correctly installed. It is also possible that the loom may have been damaged whilst maintenance was carried out in the area, and this may have started the process which led to the conductors being exposed. The insulation blanket material that had become trapped in the over-pressure relief valve indicated that the aircraft had suffered an excess pressure event at some point in the past. This could possibly have been due to the failing wiring causing the OFV to initially close and raise the cabin pressure above normal, but there was no evidence that this had actually occurred. During the Certificate of Airworthiness air test at some point prior to this de-pressurisation, pressure in the fuselage would have been deliberately raised to check the function of the over-pressure relief valves. It is possible that during this test the blanket material was ingested and that it had remained undetected as these valves are not clearly visible from the outside of the aircraft. Thermal/mechanical CBs do not necessarily operate when wires short together or to ground and the wisdom of not attempting to re-set such CBs (as was reported with the drain mast heater CB on G- DOCE) on systems that are not essential for safe continued flight is generally accepted. To do so risks, potentially, adding energy into a failure situation, thereby possibly turning a contained situation into a critical one that may be associated with multiple systems failures and/or fire. Early detection of wiring faults involving arcing, and rapid isolation of the affected systems, should be achievable with the use of the 'arc fault interrupters' now being developed. However, potential problems presently remain with such devices from unwanted interruption, especially from a common-mode perspective.
In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.