FlarePath
UK AAIB AAIB-2003-CFDAT · UK AAIB · Field investigation

Airbus A310

Stand 6, Manchester Airport, Manchester · 2003-07-15·C-FDAT

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
No injury
highest injury
—
damage

What happened

AAIB synopsis, verbatim

Airbus A310-308, C-FDAT

Conclusion

the AAIB's conclusion, verbatim
Six contributory factors combined to cause this incident: 1. Irrespective of whether an aircraft was allowed to self-park or required marshalling into position, Apron Control routinely switched on the SEDG lights. 2. The airbridge driver did not report to Apron Control that the airbridge was incorrectly parked and creating an obstruction on the stand. 3. The validity of the assumption in Apron Control that a stand was clear unless notified to the contrary was heavily dependent on telephone communications. 4. The instructions to staff regarding the reporting of stand obstructions were not optimised and the communication method was insufficiently robust to guarantee immediate contact with Apron Control. 5. The time pressure imposed on the marshaller by the additional task at Stand 10 meant that he did not properly check that the stand was clear of obstructions before marshalling the aircraft. 6. There were no controls for the SEDG or 'STOP SHORT' lights in the vicinity of the stand. Airport operator's safety action Following an internal investigation the airport operator has introduced a new procedure that when a marshaller is to be allocated to a stand, the SEDG will not be activated at any time. This will prevent an aircraft moving onto a stand before it has been properly cleared. However, a hazard still exists for aircraft allowed to self-park on some stands. The hazard arises because Apron Control will routinely switch on the SEDG on the assumption that the stand is clear unless they have been notified to the contrary. As this incident shows, current methods for staff other than marshallers (who are equipped with radios) to inform Apron Control of an obstruction are far from robust. Moreover, at the stands serving Terminals 1 and 3 there is no immediate capability for staff at or near the stand to activate a STOP signal should it become necessary to do so. Therefore, two safety recommendations are made to address the immediate problems highlighted above and to establish an effective medium term solution which more effectively conforms with the advice and guidance contained in CAP 642.

Safety recommendations

2 issuedwhat changed because of this accident
  • AAIB 2003-131issued

    Manchester Airport plc should ensure that Stand Entry Docking Guidance lighting is not activated by Apron Control until a positive communication has taken place with staff at the stand confirming that the stand is clear. Until the aircraft has parked and shut down its engines, those staff should remain available at the stand to inform Apron Control if the stand subsequently becomes obstructed.

  • AAIB 2003-132issued

    For the airbridges and stands serving Terminals 1 and 3, Manchester Airport Plc should, within a reasonable timescale, fund and develop Stand Entry Docking Guidance lighting controls and associated procedures that comply with the advice and guidance contained in Civil Aviation Publication (CAP) 642.

In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.