UK AAIB AAIB-2001-GRJXA · UK AAIB · Field investigation
Embraer EMB-145EP
Near Glasgow Airport · 2001-09-06·G-RJXA
Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
No injury
highest injury
—
damage
What happened
AAIB synopsis, verbatimEmbraer EMB-145EP, G-RJXA Summary: The crew and aircraft were assigned to operate an 0545 hrs scheduled flight from Glasgow to Manchester. The weather was fine with a light wind from the west, good visibility, air temperature 12°C and QNH 1016 HPa.
Conclusion
the AAIB's conclusion, verbatimSummary The engine fire indications were genuine and well handled by the entire crew. The Air Turbine Starter (ATS) had failed when the overrun bearings within the clutch seized as a result of operation with excessive axial load. The heat generated was sufficient to vaporise and ignite the ATS lubricating oil. The ATS fitted to G-RJXA was of a standard no longer fitted to production aircraft. At the time of the incident, the aircraft operator had already decided to replace any older standard ATS within its fleet and the modification will be mandated by the UK CAA. Consequently, no AAIB recommendations were made.
In FlarePath for this case
What an account opens
AnalyseThe Analyst and the S.I. Assistantone timeline across the recorders, precedent accidents, answers from the 1 documents with the page they came fromKeepCasebook and briefsnotes pinned to the evidence, an investigation brief, a read-only link for your team
The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.