What happened

AAIB synopsis, verbatim

Embraer EMB-145EP, G-RJXA Summary: The crew and aircraft were assigned to operate an 0545 hrs scheduled flight from Glasgow to Manchester. The weather was fine with a light wind from the west, good visibility, air temperature 12°C and QNH 1016 HPa.

Conclusion

the AAIB's conclusion, verbatim
Summary The engine fire indications were genuine and well handled by the entire crew. The Air Turbine Starter (ATS) had failed when the overrun bearings within the clutch seized as a result of operation with excessive axial load. The heat generated was sufficient to vaporise and ignite the ATS lubricating oil. The ATS fitted to G-RJXA was of a standard no longer fitted to production aircraft. At the time of the incident, the aircraft operator had already decided to replace any older standard ATS within its fleet and the modification will be mandated by the UK CAA. Consequently, no AAIB recommendations were made.