FlarePath
UK AAIB AAIB-2001-GBOPU · UK AAIB · Field investigation

Grob G115

Manchester (Barton) Aerodrome · 2001-08-09·G-BOPU

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
No injury
highest injury
—
damage

What happened

AAIB synopsis, verbatim

Grob G115, G-BOPU

Conclusion

the AAIB's conclusion, verbatim
Discussion It was concluded that the engine failed due to lack of fuel. Several opportunities existed however for the fuel gauge inaccuracy to be noticed: 1. The fuel tank had been removed during maintenance and the engineer, when refitting the tank, had not noticed that the full indication was inconsistent with the amount of fuel he had added. 2. Two instructors had accepted the 'full' indication on the fuel gauge as being correct and it was apparent that it was not common practice for pilots to reconcile the aircraft's previous flight times and fuel burn against fuel remaining and fuel uplift. [The flying club had operated two Grob 115 aircraft for 12 years, and throughout that period the fuel gauging system had always been reliable. With no visual means of checking the fuel quantity and with the perceived reliability of the fuel gauging system, they had therefore relied solely on the fuel gauge to assess fuel quantity. They had also not queried the full indication. The aircraft is not normally refuelled to full because with two occupants of medium build or larger, the maximum take-off weight for the aircraft could be exceeded. Both the instructor and student were of light build and therefore could accept the aircraft with a full tank]. Approximately 100 examples of this aircraft with this fuel tank configuration have been manufactured. Eight aircraft, operating in Australia, are equipped with the visual sight gauge. The manufacturer has no record of fuel gauging failures. In Australia however, there have been reports from operators of unreliable indications caused by corrosion. The CAA recognise that fuel gauges fitted to light aircraft can sometimes be unreliable and publish advise to private pilots accordingly. The CAA General Aviation Safety Sense Leaflet 1C, titled 'Good Airmanship Guide' emphasises that pilots should 'determine visually that you have enough fuel of the right type. If necessary, use a dip-stick to check fuel levels'... In this model of aircraft however it is not possible to check the fuel visually. Furthermore, because the fuel tank is located below and forward of the filler cap, it is not possible to 'dip' the tank. The exact amount of fuel can only be confirmed when the tank is full by overfilling the tank and allowing fuel to spill out of the filler cap Previous recommendation
In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.