UK AAIB AAIB-2000-GVCED · UK AAIB · Field investigation
Airbus A320-231
London Gatwick Airport · 2000-01-20·G-VCED
Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
No injury
highest injury
—
damage
What happened
AAIB synopsis, verbatimAirbus A320-231, G-VCED Corrigendum
Conclusion
the AAIB's conclusion, verbatimDiscussion 8.1 Door failure Examination of G-VCED showed that the fan cowl door hinges had not failed and the evidence suggested that a lack of restraint to the lower end of the doors had allowed aerodynamic loads, at around the point of take-off rotation, to forcibly hinge the doors open. The hinges had then over-travelled, causing pylon damage, and most of both doors had torn away and struck various parts of the aircraft. Correct latch engagement tensions, as indicated by handle operating loads, were impossible to confirm after the accident but had been checked less than 2 months previously; no extreme adjustment of the eyebolts was evident after the accident. Although Nos 2 and 4 latches were found open, both showed signs of having forcibly struck the aircraft and/or the runway and it appeared likely that the associated inertial forces could have caused them to open. There were no signs of latch or eyebolt failure and examination did not suggest any plausible mechanisms by which correctly engaged latches could either, disengage from the eyebolts while remaining closed, or open of their own accord, or by which latches could be mis-engaged. No previous reports of such events, or of fastened doors having failed, were found. It was therefore concluded to be highly probable that the doors had inadvertently not been latched following the pre-flight maintenance. It would be quite understandable that such an omission could result, should any distraction intervene between the closing and latching operations. Given the lack of conspicuous cues to the doors being closed but unlatched, it was also readily apparent that the condition would not necessarily be detected during the remainder of the maintenance check or the subsequent three independent walk-round inspections, particularly at night, with lighting from overhead. The previous 7 cases in a 9 year period reinforced these conclusions. In G-VCED's case, the dark blue paint on the latch handles was likely to have diminished their conspicuity somewhat, although it was judged that this would have made only a marginal difference. 8.2 Maintenance The Quality Advisory Notice and Technical Instruction that the maintainer had issued in 1999, in response to information on the previous cases circulated by the powerplant manufacturer, may have assisted in preventing the accident, but the Engineer conducting the Check had not been aware of these. A system that should have positively ensured that the instructions were brought to his attention had been discontinued some time previously, when the maintainer's operations had been re-organised. 8.3 Door modifications and procedures The aircraft modification issued by the powerplant manufacturer to apply instructions to the fan cowl doors to, 'ensure they were latched when closed' was considered unlikely to be highly effective. The measures that aimed at increasing the conspicuity of unfastened latches by painting them fluorescent red/orange or modifying them to hang down further may have been of some benefit, but were judged unlikely to significantly reduce the probability of recurrence. The aircraft manufacturer disagreed with this, noting that no cases of fan cowl door loss from aircraft with these modifications implemented had occurred, but this was not considered of great significance as the associated SBs had only been issued in mid-1999 and the service experience with the modifications was very limited. It did appear that the modification to prevent the doors from initially closing fully when lowered could provide a powerful cue to an unlatched condition and would reduce the likelihood of recurrence of this accident. The device would not prevent the doors from being fully lowered, after moving the door blocker aside, and still left unlatched. However, this would seem to be considerably less likely, as the removal of the blocker would necessitate lying beneath the doors and would, therefore, tend to be an intrinsic part of the latching operation. It is considered that a detailed assessment would be necessary to determine whether the modification would be sufficiently effective. It was categorised as a customer option. Misunderstanding of the status of the doors that could result from incorporation of the modification on some aircraft and not others, could be prevented by requiring the modification for all relevant aircraft. Two major operators are understood to be incorporating the modification on their fleets. While the aircraft damage in this case did not suggest an immediately obvious catastrophic hazard to the aircraft from this failure, the possibility cannot be dismissed. An example was provided by an accident to a different aircraft type, where numerous cases of cabin door detachment in flight occurred without the potential hazard being sufficiently recognised for effective action to be taken. This only resulted after the final case, where a fatal loss of control and in-flight break-up resulted when a detached door initially lodged on the tailplane and grossly disturbed its airflow (HS748 G- ASPL at Nailstone, UK, on 26 June 1981, AAIB Report 5/83). In addition, some of the other cases of fan cowl door loss apparently concerned A319, A321 and A330 aircraft and available information indicated that the fan cowl doors and their latching arrangements for these types were the same as for the A320. It is therefore recommended that the DGAC mandate aircraft modification aimed at appreciably reducing the likelihood of A320 fan cowl doors inadvertently remaining unlatched after maintenance. It is considered that, while measures to exhort maintenance personnel to ensure the doors are latched and to improve the conspicuity of unfastened latches may assist, they are unlikely to be fully effective and modification aimed at providing obvious indication of unlatched doors is required (Recommendation No 2000-26). Interim safeguards during the appreciable time that would likely be taken to implement the above meas
In FlarePath for this case
What an account opens
AnalyseThe Analyst and the S.I. Assistantone timeline across the recorders, precedent accidents, answers from the 2 documents with the page they came fromKeepCasebook and briefsnotes pinned to the evidence, an investigation brief, a read-only link for your team
The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.