FlarePath
UK AAIB AAIB-2000-GTVAA · UK AAIB · Field investigation

Agusta A109E Power

Arborfield Cross, Berkshire · 2000-06-17·G-TVAA

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
Minor injury
highest injury
Substantial
damage

What happened

AAIB synopsis, verbatim

Agusta A109E Power, G-TVAA

Conclusion

the AAIB's conclusion, verbatim
Discussion The common feature in the accidents to G-TVAA, G-JRSL and EC-GQX was that, a short time beforehand, the lower scissors link had been installed in the incorrect orientation. The combined effect of the spherical bearing within the link running out of travel plus contact between the cup washer and the link was to impart a bending load to the swashplate attachment bolt. This resulted in a fatigue crack developing in the bolts of all helicopters and led to the in-flight failure of the bolt in the case of G-TVAA and EC-GQX. The same probably happened to G-JRSL but could not be established beyond doubt; the fatigue cracking was different in nature to that of the bolt from G- TVAA in that it resulted from a reverse bending mechanism, the derivation of which was not determined. The fact that it was possible to install the lower scissors link incorrectly meant that the design did not comply with BCAR Section G4-8. Additionally, three intact helicopters were found to have the bevelled washer incorrectly positioned inboard of the link. Since no maintenance had taken reportedly taken place that required disassembly of these components, it was concluded that the helicopters had been manufactured in this configuration. It was found that the change in linkage geometry that resulted from the bevelled washer being positioned inboard of the link caused the upper part of the cup washer rim to be in close proximity to the link outer face. There was physical evidence, which indicated that even when the link was installed in its correct orientation, contact occurred, at high pitch settings, between the cup washer and link. Contact forces would have been light however, and thus probably had little bearing on the accidents investigated here other than perhaps using up the fatigue initiation period. The link retaining nuts on all the helicopters examined during the investigation were found to be in or close to a thread-bound condition on their respective swashplate bolts. It was thus concluded that an insufficient margin of thread was provided for the installation. It is possible that any tendency for thread binding could result from an adverse accumulation of tolerances within the stack-up of components. Additionally, there could be varying degrees of bedding down of the bolt head within counter-bore on the inner face of the swashplate. It was reported that difficulty was generally encountered in lining up one of the nut castellations with the split pin hole in the bolt, whilst at the same time meeting the Maintenance Manual torque requirement. A high assembly torque could thus result in a progressive bedding down of the bolt head in service, with an associated reduction in clamping force between the components. There would then be an increased possibility of the nut reaching the end of the threads on a subsequent reassembly of the components. A loose component stack-up for any reason in an installation such as this would be undesirable, as it could generate bending loads, as opposed to pure shear loads, with an attendant possibility of a fatigue crack developing.
In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.