UK AAIB AAIB-2000-GDJAR · UK AAIB · Field investigation

Airbus A320-231

Over the English Channel · 2000-06-10·G-DJAR

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
Minor injury
highest injury
—
damage

What happened

AAIB synopsis, verbatim

Airbus A320-231, G-DJAR

Conclusion

the AAIB's conclusion, verbatim
Discussion The defects reported on the aircraft the previous day were inappropriately addressed by maintenance. Such trouble shooting as there was failed to detect the No 2 conditioning pack NRV damage and the condenser outlet duct was reconnected using an unapproved technique. This resulted in the duct again becoming disconnected and a subsequent loss of cabin pressurisation. There were some mitigating circumstances in that the individuals were under considerable pressure to return the aircraft to service and the requisite spares were not available. The maintenance company's internal investigation concluded that there had been significant deviations by staff from laid down internal procedures and a failure of the engineering management organisation to support line staff. It also found that the company's Reliability Monitoring System had failed to highlight the recurrent problems with the No 2 air-conditioning pack. It recommended that all staff at Gatwick be briefed on the limits of their authority and the concession procedure. The passengers had suffered a 16 hours delay to their departure, having spent the night in a Gatwick hotel, and during the delay at the airport they had not been kept updated on their likely departure time. Some later felt that they had been mislead about the maintenance status of the aircraft when they had enquired whether it was the aircraft that had suffered some defects the previous day. The cabin altitude peaked briefly during the event at 14,000 feet and was above 9,000 feet for some 7 minutes and 30 seconds. This would not have constituted a serious health threat to a medically fit person but was undoubtedly a period of confusion and distress to many of the passengers. Although most were aware of some of the information from the pre-flight safety briefing video for most the details were forgotten. The deployment of the oxygen masks, some tangled, and the smell of the hot oxygen generators coupled with confusion on the use of the masks and a lack of confidence in the system performance created for some a state of high anxiety. In the absence of the Airbus automatic message, an early PA announcement to re-assure the passengers and redefine the use of the oxygen system and its performance would undoubtedly have helped matters. It is therefore recommended that:- Recommendation 2002-5 The CAA should bring to the attention of AOC holders and the JAA, the circumstances of this incident and the advantages of using the 'Pre-Recorded Announcement' (PRA) facility when it is provided as a manufacturers' option. Furthermore the CAA should recommend to AOC holders that they should review their post decompression procedures and, where appropriate, introduce a public address announcement. Recommendation 2002-6 The Central JAA should review the adequacy of the requirements detailed in JAR-OPS 1.285 for the briefing of passengers and in particular the requirements relating to the provision of 'picture type instructions' indicating the operation of emergency equipment and the demonstration of the use of oxygen equipment, and amend as necessary.
In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.