0
fatal
0
serious
No injury
highest injury
—
damage

What happened

AAIB synopsis, verbatim

Aerospatiale AS355F2 Ecureuil II, G-CAMB

Conclusion

the AAIB's conclusion, verbatim
The manufacturer stated that the pattern of interdendritic fracture development from the thermal fatigue initiation, was indicative of rapid creep assisted crack growth. The company was unaware of any way in which such fractures could form other than following exposure to high turbine temperatures, usually associated with engine start-up, in excess of the limits given in the Model 250 Operation and Maintenance Manual. The operator reported that the pilots who flew G-CAMB did not consider that the engines showed any tendency to exceed starting temperature limits and in general did not exceed 850°C. The aircraft was fitted with two batteries and the extra capacity helps the starting process. The operator pointed out that G-CAMB was not being operated in a commercial or training environment. The operating philosophy placed great emphasis on safety and as a "no blame" culture was promoted he was confident that crewmembers would report any observed overtemperature events. The pilot is required to monitor five parameters during engine start; gas generator rotation speed (N1), Turbine Outlet Temperature (TOT), power turbine rotation speed (N2), oil pressure and elapsed time. The TOT rises rapidly when fuel is introduced during the start cycle and the temperature profile can show two peaks before is stabilises at IDLE. There is a temperature band (810 to 927ûC) above the primary limit which may be entered for up to 10 seconds and a higher band (927 to 999ûC) which requires turbine inspection. If the ultimate limit of 999ûC is exceeded wheel replacement is mandatory. In some aircraft installations of the Model 250 a TOT gauge is available which records exceedances; a light on the gauge illuminates, and the light can only be switched off through a lock-switch, normally by maintenance personnel. No such gauge system is currently made available to operators of the AS355F2 Ecureuil II by the aircraft manufacturer. Given that an uncontained turbine burst can result from a hot start or other temperature exceedance the following recommendation is made:-
In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.